Glazed Screens Non FD
Code dBRw Glass Nominal
Thickness
Fire Rating BS EN 12600- 02 BS6206- 1981 DRW Ref
GS6.8A36 36(0;-3) GPS6.8 7mm N/A 1B1 Class A GS6.8A36
GS8.8A37 37(0;-2) GPS8.8 9mm N/A 1B1 Class A
GS10.8A39 39(-1;-3) GPS10.8 11mm N/A 1B1 Class A
GS12.8A40 40(-1;-3) GPS12.8 13mm N/A 1B1 Class A
GS16.8A41 41(-1;-2) GPS16.8 17mm N/A 1B1 Class A
Glazed Fire Screens (FD Rated)
Code dBRw Glass Nominal
Thickness
Fire Rating BS EN 12600- 02 BS6206- 1981 DRW Ref
GFP7-30.0-34 34(0;-3) GFP7 7.9mm 30/0 3B3 Class C
GFP12-60.0-36 36(-1;-3) GFP12 12.3mm 60/0 2B2 Class B
GFP16-60.30-39 39(-1;13) GFP16 17.3mm 60/30 2B2 Class B
GFP25-60.60-40 40(-1;-3) GFP25 26.6mm 60/60 1B1 Class A
GFP25eg-60.60-43 43(-1;-4) GFP25eg 30.4mm 60/60 1B1 Class A