FD30/0, 30/30, 60/0, 60/30 & 60/60 Timber Framed Glazed Firescreens
-
Timber Firescreen Overview (click here)
The Forza range of standard elevations assists in the understanding of the maximum sizes of fire glass suitable for 30 or 60 minute fire integrity/ insulation and also guides the specifier with regard to the impact recommendations contained in the various British Standards and Building Control Approved Documents. Example Standard Elevations
SC FD30/0 GFP7
(click here)SF FD30/30 GFP16
SH FD60/0 GFS12
(click here)SE FD60/30 GFP 16
(click here)SP FD60/60 GFP25
(click here)SN FD60/60 Mullion Free
(click here)Minimum Dimensions Timber Frame (click here) Minimum Dimensions MDF Frame (click here)
Maximum Glass Size per Frame
MAX HT
ASSO.W
MAX W
ASSO HT
FD30/0 GFP7
2940
900
1430
1700
FD30/30 GFP16
2940
1600
1750
2370
FD60/0 GFS12
2850
1400
2850
2370
FD60/60 GFP25
2940
1300
1850
1800
-
Acoustic availability (click here)
Rating according to BS EN ISO 717-1: 2013 from tests and measurements conducted In accordance with BS EN ISO 10140-2:2010.
dB Rw Rating GFP7 34(0;-3)dB. GFP16 39(-1;-3)dB. GFS12 34(-2;-3)dB. GFP25 40(-1;-3)dB
-
Structural & Mechanical (click here)
Forza glazed timber frame screens Tested in accordance with BS5234-2 (Methods - Annex A/C/E/F) achieved performance levels summarised as grade requirement SEVERE DUTY and is documented in Certificate reference FTS.12/01 (Drawing FZD0514/2).
Forza have carried out CAD FEA(Finite Element Analysis) imposed load simulation tests on a number of standard elevations containing our preferred range of fire glasses within our timber screens ,the results of which (+15% margin adjusted) indicate the screen performance for the imposed load to be within maximum displacement requirements. (Drawing FZD0509/5)
Glass Impact Performance Class to BS EN 12600: GFP7 3B3. GFP16 2B2. GFS12 1C1. GFP25 1B1
Glass impact classes for toughened glass so that it provides containment recommended in BS6180-2011 for a 'Free Path:
A. for a free path upto 1500mm. Min. class 3. BSEN12600
B. for a free path greater than 1500mm. Min. class 1. BSEN 12600 Screen Features
Flush to door & panel (click here) Double glazed glass position (click here) Solid timber panel module (click here) Environment (click here)
Requested FSC Timber. Forza choose to make a conservative claim of FSC "mixed 67%" for its FSC composite products although many are at mix 70% content. Certificate Nos: FSC ®: INT-COC-002502: PEFC™: INT-PEFC-COC-002502
-
Finishes (click here)
Lacquer: Hand sprayed two coat A/C lacquer 20% gloss Paint: Commercially available RAL colours. Standard 20% gloss.
Forza Keyfaq's are designed as a fast track route to answer questions you may have relating to timber fire doors, frames and screens utilised in the commercial interiors construction market of offices , education health hotel and retail environments .
In addition to data on FD30 & FD60 Timber Firescreens Forza have the following Keyfaq's data sheets.
1.
FD30 (30 minute) Timber Fire Door in a Timber or MDF Flush
Frame
2.
FD30 (30 minute) Timber Fire Door in a Timber Rebated
frame
3.
FD30 (30 minute) Timber Fire Door in a Aluminium frame
4. FD30
(30 minute) Timber Fire Door in a Steel frame
5.
FD60 (60 minute) Timber Fire Door in a Timber or MDF Flush
frame
6.
FD60 (60 minute) Timber Fire Door in a Timber Rebated
frame
7. FD60
(60 minute) Timber Fire Door in a Steel frame
8.
FD90 (90 minute) (FCH) Timber Fire Door in a Timber Flush
frame
9.
FD90 (90 minute) (FCW) Mineral core Fire Door in a Mineral
Composite frame
10.
FD120 (120 minute) (FCW) Mineral core Fire Door in a Mineral
Composite frame
11. Timber Door
& Frame Acoustics
12. CE Mark
FD30 (30 minute) and FD60(60minute) Timber Door Sets
13. Approved
Documents M and K 2013 :
14. Ironmongary
Installation
15.
Design Feature Timber Doorframes
16. FD30 & FD60 Timber Firescreens
17. Imola
& Bespoke Timber Partition Systems
18.
Veneer, Laminate or Painted Panels & Feature Walls
19. Veneer,
Timber, Laminate, Lacquer and The Environment
20. General Guidance